Skip to main content
Three-Way Clamp-End Ball Valve family photograph
Manual three-way clamp-end family photograph. The additional dimension table is an actuated-family reference; confirm the exact selected configuration and port pattern.

Ball Valves

Three-Way Clamp-End Ball Valve

Catalogue family · DN15-DN80 · Clamp-end
Catalogue size coverageDN15-DN80
Published L referencesDN15-DN50 only
ConnectionClamp-end
Port patternConfirm selected routing
Engineering review & quotation scope
Review the available technical parameters, drawings, or sheets below. Final configuration, dimensions, and required documentation are confirmed against your RFQ.
Quick Spec Configurator — Click chips to attach to your RFQ or BOM:
Size Range
Pressure
Material / Seat
Operation
Bundle Matched Accessories & Documentation (Optional 1-Click Add-On):
⇄ Engineering Unit & Standard Converter (DN ↔ NPS / PN ↔ Class / MPa ↔ PSI)+

Product specifications

Specifications

Catalogue size coverage
DN15-DN80
Published L references
DN15-DN50 only
Connection
Clamp-end
Port pattern
Confirm selected routing

Published values describe the available catalogue reference. Final configuration is confirmed against the RFQ.

Catalogue family reference

Three-Way Clamp-End Ball Valve: installation-length references

The actuated-family catalogue table lists DN15-DN80, but L is blank for DN65 and DN80. Only the six printed L values are transcribed below; the missing lengths have not been inferred. These values do not establish dimensions for every manual, capped or regular configuration.

Three-Way Clamp-End Ball Valve · L reference dimensions, mm
Nominal sizeL (mm)
DN15100
DN20100
DN25111
DN32140
DN40160
DN50180
Clamp-end reference schematic showing dimension L
Simplified connection schematic, not to scale and not a fabrication drawing. Confirm the complete end and assembly dimensions against the selected order drawing.

Why are DN65 and DN80 not in the L table?

The source lists these sizes but leaves their L cells blank. Send the size and end requirements so the selected order drawing can be confirmed; no length has been guessed from neighbouring rows.

How do I select the flow path?

Supply a piping sketch identifying all three ports, the required connected paths at each position and any shut-off requirement. L-port, T-port, travel limits and actuator fail position must be confirmed; a three-way exterior does not establish an all-ports-closed position.

What should an automated assembly RFQ include?

State pneumatic or electric operation, control supply, signal and feedback requirements, fail position if needed, installation envelope, medium, pressure and temperature. Do not select actuator size from DN alone.

Compare all ball valves · Prepare a valve RFQ · Compare seat requirements

Three-way clamp family: interface diameter references

Use these catalogue clamp-interface diameters together with the original L table above, not as a universal ferrule standard or guaranteed mating fit.

Actuated three-way clamp family: source interface diameter
Nominal sizeCatalogue clamp interface (mm)
DN1550.5
DN2050.5
DN2550.5
DN3250.5
DN4050.5
DN5064
DN6577.5
DN8092

DN65 and DN80 have interface references, but their L cells remain blank in the source and no lengths are inferred. Confirm sealing-face profile, tube dimensions, gasket and selected body drawing. Interface diameter alone does not establish compatibility, hygienic approval or the actuator envelope.

Compare all ball valves · Prepare a valve RFQ · Compare seat requirements

Procurement Summary

A three-way quick-install clamp-end ball-valve family for defined routing requirements. Compare the published body-length references, then specify the mating ends, required port connections and switching sequence.

Document Status

  • Catalogue-family dimension reference and connection schematic
  • Selected order drawing and required document scope: confirm with your RFQ

Required documents are confirmed for the quoted product and project requirements.

WhatsApp