Valve Actuation
AD/AS Scotch-Yoke Pneumatic Actuator
Review the available technical parameters, drawings, or sheets below. Final configuration, dimensions, and required documentation are confirmed against your RFQ.
⇄ Engineering Unit & Standard Converter (DN ↔ NPS / PN ↔ Class / MPa ↔ PSI)+
Product specifications
Specifications
- AD catalogue references
- AD50-AD200
- AS catalogue references
- AS50-AS200
- Operating variants
- Double / single acting
- Mounting and output
- Confirm selected assembly
Published values describe the available catalogue reference. Final configuration is confirmed against the RFQ.
Catalogue family reference
AD/AS Scotch-Yoke Pneumatic Actuator: configuration-specific dimension references
AD and AS have separate L tables. The numbers in these model names are catalogue identifiers, not valve DN sizes or guaranteed output torque. Matching a model suffix does not establish identical length or direct interchangeability. L is only one envelope dimension; do not use it as a mounting-hole, shaft or bracket specification.
| Catalogue model | L (mm) |
|---|---|
| AD50 | 162 |
| AD65 | 204 |
| AD80 | 249 |
| AD100 | 309 |
| AD125 | 404 |
| AD140 | 436 |
| AD160 | 514 |
| AD185 | 579 |
| AD200 | 605 |

| Catalogue model | L (mm) |
|---|---|
| AS50 | 256 |
| AS65 | 314 |
| AS80 | 418.5 |
| AS100 | 498 |
| AS125 | 608 |
| AS140 | 683 |
| AS160 | 781 |
| AS185 | 881 |
| AS200 | 982 |
How should I select an actuator for a valve?
Supply the valve break/run/end torque profile and its basis, minimum available air pressure, operating duty, travel, environmental conditions and required design margin. Match the entire torque curve and selected spring configuration rather than valve DN or model suffix alone.
Does single acting automatically mean fail closed?
No. Specify the required safe position and verify spring action, valve port mapping, rotation direction, travel stops and control arrangement for the complete assembly. No fail-safe or safety-integrity certification is implied.
Will it fit the existing 63000RA or AT mounting?
No direct compatibility is established. These remain distinct catalogue families. Confirm shaft engagement, hole pattern, bracket, coupling, accessory interfaces and complete dimensional drawing before substitution.
Compare valve actuation · Prepare a valve RFQ · Compare seat requirements
- AD/AS Scotch-Yoke Pneumatic Actuator
- Three-piece threaded valve: separate selection
- Three-piece butt-weld valve: separate selection
- Three-piece socket-weld valve: separate selection
AD/AS mounting and CH references
The following entries retain the catalogue ISO-column references and CH drawing labels. They are dimensional selection references, not an ISO certificate or a promise of direct fit to every valve.
| Model | Source ISO column reference | CH (mm) |
|---|---|---|
| AD50 | F03 / F05 / F07 | 11 x 11 |
| AD65 | F05 / F07 | 14 x 14 |
| AD80 | F07 | 17 x 17 |
| AD100 | F07 / F10 | 22 x 22 |
| AD125 | F07 / F10 | 22 x 22 |
| AD140 | F10 / F12 | 27 x 27 |
| AD160 | F14 | 36 x 36 |
| AD185 | F14 | 36 x 36 |
| AD200 | F16 | 46 x 46 |
| Model | Source ISO column reference | CH (mm) |
|---|---|---|
| AS50 | F03 / F05 / F07 | 11 x 11 |
| AS65 | F05 / F07 | 14 x 14 |
| AS80 | F07 | 17 x 17 |
| AS100 | F07 / F10 | 22 x 22 |
| AS125 | F07 / F10 | 22 x 22 |
| AS140 | F10 / F12 | 27 x 27 |
| AS160 | F14 | 36 x 36 |
| AS185 | F14 | 36 x 36 |
| AS200 | F16 | 46 x 46 |
Slash-separated F references remain alternatives; identify the required drilling and chosen arrangement. CH is only the labelled square dimension, not the full coupling specification. Confirm hole pattern, shaft shape and engagement depth, bracket, fasteners, torque curve and selected assembly drawing. Matching references do not establish retrofit compatibility with 63000RA, AT or a particular valve.
Procurement Summary
Compare AD double-acting and AS single-acting scotch-yoke actuator models using separate L, mounting-reference and CH tables. Confirm torque, air supply, shaft engagement and the selected assembly drawing.
Document Status
- Readable catalogue dimension references and selection notes
- Complete mounting drawing, shaft/coupling details and control scope: confirm with the RFQ
Required documents are confirmed for the quoted product and project requirements.